HUO Xiao-min,LI An,LI Jun-ling,WANG De-qing.Optimization of Ni-Cr Foam Alloy Electroplating Technology by Orthogonal Test[J],43(1):95-102
Optimization of Ni-Cr Foam Alloy Electroplating Technology by Orthogonal Test
Received:July 29, 2013  Revised:September 25, 2013
View Full Text  View/Add Comment  Download reader
DOI:
KeyWord:polyurethane  electro-plating  coating thickness  deposition rate  Cr content
           
AuthorInstitution
HUO Xiao-min School of Materials Science and Engineering, Dalian Jiaotong University, Dalian , China;Dalian Institute of Product Quality Supervision and Inspection, Dalian , China
LI An Dalian Institute of Product Quality Supervision and Inspection, Dalian , China
LI Jun-ling School of Materials Science and Engineering, Dalian Jiaotong University, Dalian , China
WANG De-qing School of Materials Science and Engineering, Dalian Jiaotong University, Dalian , China
Hits:
Download times:
Abstract:
      Objective To obtain the optimal parameters during the electrodepositing of Ni-Cr foam alloy. Methods The main factors including the thickness, deposition rate and chrome content of the coating layer were explored by orthogonal design experiment. The coating indices for cross-section microstructure and surface morphologies were investigated by the test methods. Results A 24. 09 μm thick layer of uniform and bright coating was obtained with 14. 76 wt% of Cr at the deposition rate of 0. 4198 mg /( cm2 ·min) in the solution of 125 g / L CrCl3 ·6 H2 O with a pH of 2. 0 and current density of 28 A / dm2 at 25 ℃ for sixty minutes. Conclusion Temperature was the most important factor affecting the Ni-Cr alloy layer thickness and deposition rate in the range of 25 ~ 40 ℃ , and the concentration of CrCl3 ·6 H2O and complexant in plating solution were the most important factors affecting the chrome content of the coating layer.